Heat Pump Terminology 101

Your heat pump terminology cheat sheet: A to Z terms explained in simple language. Understand components, efficiency metrics, and settings for smarter buying and better comfort.

Heat Pump Terminology 101
Heat Pump Terminology List

A quick, skimmable A–Z of heat-pump terms for homeowners. Click a letter to jump, then tap “Back to top.”

A A

  • Accumulator: Small tank in the suction line that protects the compressor from liquid refrigerant
  • AHRI (Air-Conditioning, Heating & Refrigeration Institute): Independent body that certifies and lists equipment performance
  • Air handler: Indoor unit with blower and coil that moves conditioned air through ducts
  • Air-source heat pump (ASHP): System that moves heat between outdoor air and your home
  • Automatic/adaptive defrost: Control logic that defrosts only when needed to save energy
  • Auxiliary heat (AUX): Automatic electric or gas backup that kicks in when the heat pump can’t meet demand
↑ Back to top

B B

  • Backup heat: Any secondary heat source used with a heat pump, such as heat strips or a furnace
  • Balance point: Outdoor temperature where heat pump output equals the home’s heat loss
  • Base pan heater: Electric heater under an outdoor unit to melt ice in cold climates
  • Blower (ECM): Variable-speed indoor fan motor that adjusts airflow efficiently
  • Branch box: Refrigerant distribution manifold for multi-zone mini-splits
  • Brazing: High-temperature joining method used on copper refrigerant lines
  • BTU (British Thermal Unit): Heating/cooling capacity measure; 12,000 BTU equals 1 ton
  • Buffer tank: Small water tank that stabilizes temperatures in air-to-water systems
  • Bivalent point: Temperature where a dual-fuel system switches from heat pump to furnace
↑ Back to top

C C

  • Capacity: Amount of heat a unit can move, expressed in BTU/h or tons
  • CEE tiers: Utility program efficiency tiers used for rebates and incentives
  • CFM (Cubic Feet per Minute): Airflow rate through ducts and equipment
  • Charge (refrigerant): The precise amount of refrigerant in a sealed system
  • Clearances: Required space around equipment for airflow, service, and safety
  • Coefficient of Performance (COP): Heating efficiency ratio of heat output to electrical input
  • Cold-climate heat pump (CCHP): Unit designed to maintain capacity and efficiency in very low temperatures
  • Compressor (scroll/rotary/inverter): The “pump” that raises refrigerant pressure and temperature
  • Condensate drain: Tubing that removes water from the indoor coil during cooling or dehumidifying
  • Condenser coil (outdoor coil): Coil that rejects or absorbs heat outside, depending on mode
  • Crankcase heater: Warms compressor oil to prevent refrigerant migration when off
↑ Back to top

D D

  • Defrost cycle: Temporary reversal in winter to melt frost off the outdoor coil
  • Demand response: Utility signal that lets your system reduce load during peak hours
  • Desuperheater: Heat-recovery loop that preheats domestic hot water from compressor waste heat
  • Ducted mini-split: Mini-split system connected to small ductwork
  • Ductless mini-split: Zoned system with wall, floor, or ceiling cassettes and no ducts
  • Dual fuel: Heat pump paired with a gas furnace for backup or extreme cold
↑ Back to top

E E

  • EEV (Electronic Expansion Valve): Precise, motor-driven metering device for refrigerant flow
  • EER (Energy Efficiency Ratio): Cooling efficiency at a single test condition
  • Electric resistance heat: Simple electric backup heat using heat strips
  • Emergency heat (EM heat): Manual mode that forces backup heat only
  • Energy Star: U.S./Canada label for products meeting high efficiency standards
  • Expansion valve (TXV/EEV): Device that drops refrigerant pressure before the evaporator coil
  • External static pressure (ESP): Resistance to airflow from ducts and components
↑ Back to top

F F

  • Fan coil: Indoor coil and fan assembly for hydronic or refrigerant systems
  • Filter (MERV rating): Air filter that protects equipment and indoor air quality
  • Flare fitting: Mechanical connection on line sets, common in mini-splits
  • Frost sensor: Sensor that triggers defrost to protect the outdoor coil
↑ Back to top

G G

  • Glide (refrigerant temperature glide): Temperature range during phase change in blended refrigerants
  • Ground-source heat pump (GSHP): Uses buried loops or wells for stable ground temperatures
↑ Back to top

H H

  • Heat exchanger: Surface where refrigerant and air or water trade heat
  • Heat pump water heater (HPWH): Uses a small heat pump to heat domestic hot water
  • Heat strip (heat kit): Electric resistance elements installed in the air handler
  • HRV/ERV (Heat/Energy Recovery Ventilator): Ventilation devices that exchange heat and, for ERV, moisture
  • HSPF2 (Heating Seasonal Performance Factor 2): Newer seasonal heating efficiency metric for air-source heat pumps
  • Humidity control: Ability to remove moisture in cooling or use reheat strategies
  • Hyper-heat/low-ambient: Maker terms for models that keep strong capacity in sub-freezing temps
↑ Back to top

I I

  • Indoor unit (head): The room-side unit in a ductless system
  • Intelligent defrost: Algorithm that reduces unnecessary defrost cycles
  • Inverter-driven compressor: Variable-speed compressor for comfort and efficiency
↑ Back to top

K K

  • kWh (kilowatt-hour): Unit for measuring electrical energy use on your utility bill
↑ Back to top

L L

  • Latent heat: Moisture removal part of cooling; separate from sensible change
  • Line set: Insulated copper lines carrying refrigerant between indoor and outdoor units
  • Load calculation: Engineering estimate of a home’s heating and cooling needs
  • Lockout temperature: Set temperature where backup heat is enabled or disabled
  • Low ambient kit: Accessories that allow cooling or reliable operation in cold outdoor temps
↑ Back to top

M M

  • Manual D: ACCA method for designing duct systems
  • Manual J: ACCA method for residential load calculations
  • Manual S: ACCA method for proper equipment selection
  • MERV (Minimum Efficiency Reporting Value): Filter rating scale from 1 to 16
  • Micron gauge: Tool that verifies deep vacuum quality during install/service
  • Microchannel coil: Thin, all-aluminum coil design with low refrigerant volume
  • Mini-split: Modular heat pump system serving one or more zones
  • Monobloc: All-in-one outdoor air-to-water heat pump unit
  • Multi-split: One outdoor unit serving several indoor heads or zones
↑ Back to top

N N

  • NEEP Cold Climate list: Regional list of heat pumps that meet cold-climate criteria
  • Nitrogen purge: Flow of nitrogen during brazing to prevent oxidation
  • Noise rating (dBA): Sound level specification for indoor or outdoor units
↑ Back to top

O O

  • O/B reversing valve wire: Thermostat signal that switches between heat and cool
  • Outdoor reset (weather compensation): Control that adjusts output based on outdoor temperature
  • Outdoor temperature sensor: Sensor used for defrost, lockouts, and efficiency controls
  • Outdoor unit: Weather-exposed section containing the compressor and coil
  • Oversizing: Choosing equipment with too much capacity, causing short cycling and discomfort
↑ Back to top

P P

  • Plenum: Main supply or return air chamber attached to the air handler
  • Pressure test: Nitrogen pressurization step to verify leak-free refrigerant piping
↑ Back to top

Q Q

  • Quick-connect line set: Pre-charged or mechanical connections marketed for simplified installs
↑ Back to top

R R

  • R-32: Lower-GWP refrigerant increasingly used in residential heat pumps
  • R-410A: Common residential refrigerant being phased down due to higher GWP
  • R-454B: Newer lower-GWP replacement for R-410A in many systems
  • Radiant floor (emitter): Hydronic floor system paired with air-to-water heat pumps
  • Reheat dehumidification: Method that cools then reheats air to remove moisture without over-cooling rooms
  • Refrigerant: Working fluid that absorbs/releases heat as it changes state
  • Reversing valve: Four-way valve that switches the system between heating and cooling
  • Return air: Air pulled back to the air handler to be conditioned
↑ Back to top

S S

  • SCOP (Seasonal COP): Seasonal efficiency metric common outside North America
  • SEER2 (Seasonal Energy Efficiency Ratio 2): Updated U.S./Canada seasonal cooling efficiency metric
  • Sensible heat ratio (SHR): Share of cooling that lowers temperature versus removing moisture
  • Setback strategy: Thermostat scheduling that changes setpoints when you’re away or asleep
  • Short cycling: Rapid on/off operation caused by oversizing or control issues
  • Sizing (right-sized): Matching equipment capacity to the home’s load
  • Snow hood: Shield that keeps outdoor coils clear in snowy sites
  • Split system: Standard setup with separate indoor and outdoor sections
  • Static pressure: Resistance to airflow in ducts; critical for proper airflow
  • Subcooling: Liquid refrigerant temperature below saturation for reliable feeding of the valve
  • Superheat: Vapor refrigerant temperature above saturation to protect the compressor
  • Supply air: Air leaving the air handler headed to rooms
↑ Back to top

T T

  • Thermostat (heat pump): Control that properly handles O/B, AUX, and staging for heat pumps
  • Time-of-use rates (TOU): Utility pricing that varies by time; useful for shifting operation
  • Ton: 12,000 BTU/h of cooling or heating capacity
  • Two-stage/variable-speed: Equipment that modulates output for comfort and efficiency
↑ Back to top

U U

  • UL/CSA: Safety certification marks for electrical/mechanical equipment
  • Utility rebate: Cash or bill credits offered for qualifying high-efficiency installations
↑ Back to top

V V

  • Variable-speed drive (VFD): Electronics that control motor speed in compressors or fans
  • Vapor injection: Advanced compressor tech that boosts cold-weather heating capacity
  • Ventilation (ERV/HRV): Fresh-air systems that pair well with tight, efficient homes
  • VRF/VRV (Variable Refrigerant Flow/Volume): Multi-zone systems with advanced controls
↑ Back to top

W W

  • Water-source heat pump (WSHP): Uses a water loop, well, or lake for the heat source/sink
  • Weather compensation: See outdoor reset; adjusts output to outdoor conditions
  • Wind baffle: Accessory that stabilizes airflow across the outdoor coil in gusty locations
↑ Back to top

Y Y

  • Y1/Y2 calls: Thermostat signals that request first or second stage of cooling/heating
↑ Back to top

Z Z

  • Zone control: Dampers and controls that split a ducted home into independent zones
  • Zoning (ductless): Using multiple indoor heads so each room has its own setpoint
↑ Back to top

References:

Conclusion:

This glossary is heat pump specific and intentionally overlaps with our full HVAC glossary. Use them together: this page for heat-pump terms, the full glossary for broader HVAC lingo. If we missed a term you need, please let us know and we’ll add it.