How Efficient Are Heat Pumps? Ratings, COP and Real Costs
Understand heat-pump COP, SEER2 and HSPF2, separate efficiency from capacity, and compare costs using stated conditions and current incentives.

Heat pumps can deliver more heat than the electricity they consume because they move environmental heat into the building. Their efficiency varies with source temperature, delivery temperature, load, equipment and installation. A rating or a percentage alone cannot predict a household bill.
What COP means
Key Fact
Coefficient Of Performance
COP Of 3The coefficient of performance (COP) compares useful heat delivered with energy input. Both must use the same energy units, and the comparison must state which parts of the system are included. At a COP of 3, the heat pump delivers three units of heat for each unit of energy it uses under those conditions. That is 300% when expressed as an output/input percentage; it does not mean the system creates energy.
Source: U.S. Department of Energy.
For arithmetic clarity, COP 2.44 corresponds to 244%, while 300–450% corresponds to COP 3.0–4.5. These are conversions, not promised performance ranges. Include fans, pumps, defrost and backup when the comparison calls for whole-system energy use.
Seasonal ratings and product classes
SEER2 describes seasonal cooling efficiency; EER2 describes cooling efficiency at specified conditions; HSPF2 describes seasonal heating performance. They do not replace design-condition capacity data. Older SEER and HSPF values use different test procedures and should not be treated as identical numbers.
Federal minimum requirements depend on product class, date and, for some AC products, region. ENERGY STAR is a voluntary program with its own criteria. Check the current ENERGY STAR heat-pump criteria and the exact matched-system certificate rather than using an obsolete universal SEER 14/HSPF 8.2 rule. Geothermal products also have distinct categories and test conditions.
Cold weather changes both output and input
Compare the exact model's capacity and COP at the home's winter design condition with its calculated heating load. Cold-climate equipment is designed for colder operation, but no single outdoor temperature marks an efficiency collapse for every heat pump.
Backup can change seasonal electricity use significantly. Ground- and water-source systems can have more stable source conditions, while loop pumping, water quality and supporting equipment still matter. See cold-climate performance and water-source heat pumps.
A transparent operating-cost example
Suppose, purely as an illustration, a home needs 10,000 kWh of delivered heat over a period. At an assumed whole-period COP of 2.5, the heat pump uses 4,000 kWh. At an assumed electricity price of $0.20/kWh, that costs $800, excluding fixed charges and unrelated use.
Change the load, achieved COP, backup contribution or tariff and the result changes. For a furnace, compare delivered heat using fuel energy content, achieved efficiency, fuel price and applicable fixed charges. A fixed annual saving or percentage bill reduction without those inputs is not a reliable decision aid.
Installed cost and current incentives
Compare itemized quotes for equipment, ducts or emitters, electrical work, backup, permits, commissioning and warranty. A low equipment-only price is not the installed project cost.
As checked October 30, 2026, federal homeowner credits under Sections 25C and 25D ended for the relevant post-2025 property/expenditures. The IRS Form 5695 instructions describe the termination and applicable timing. Do not subtract a former federal credit from a new 2026 quote. State and utility programs require separate current eligibility checks.
Conclusion
Evaluate heat-pump efficiency with the right rating, operating conditions and system boundary. Combine that evidence with the home's load, local prices and complete quotes using our heat-pump buying guide.
Continue with our heat-pump guides for related homeowner decisions.

Scott Harding
Scott is the main author of DIY Home Comfort. Learn more about the team and our approach on the About page.